Ελληνικά

Progress in Calibration of Large Aperture Diffractive Lenses in the High Power Laser Physics Joint Laboratory of Shanghai Institute of Optics and Mechanics

142
2023-10-14 10:22:56
Δείτε τη μετάφραση

Recently, the High Power Laser Physics Joint Laboratory of Shanghai Institute of Optics and Fine Mechanics, Chinese Academy of Sciences, proposed a single exposure interferometric calibration method for large aperture diffractive lenses, which provides strong support for the engineering application of large aperture diffractive lenses. The relevant achievements are published in Optics Letters as "Absolute measurement of focusing properties of a large aperture diffractive lens".

Compared to reflective focusing lenses, diffractive optical elements are designed flexibly, have a large aperture, are lightweight, suitable for various wavebands, and can achieve complex optical functions. Photonic sieves and zone plates are typical representatives of diffractive lenses. Considering that diffraction elements are composed of a large number of microstructures, deviations are inevitable during the machining process, so performance calibration is necessary before use.

In this study, researchers used the natural background light of a large aperture diffractive lens as a reference and entered the shear interference system together with the focused beam. Based on the interference pattern recorded by the detector, the wavefront gradient of the focused beam relative to the background light is first obtained using Fourier analysis, and then the transmitted wavefront is reconstructed using the mode method. Finally, the focal length and focal spot morphology of the diffractive lens are numerically calculated. The experimental results of a 210mm aperture diffractive lens meet theoretical expectations. Ultra large aperture zone plates and photon sieves can be used for space interferometric telescopes. The self supporting beam splitting photon sieve is suitable for focusing imaging of EUV and soft X-ray. Multi focal photon sieves can be used for X-ray interference diagnosis of plasma.

This work was supported by the National Natural Science Foundation of China and the Chinese Academy of Sciences' pilot A program.

Figure 1. Measurement Optical Path of Large Aperture Diffractive Lens

Figure 2. Experimental results of self-developed shear interferometer and measurement

Source: Shanghai Institute of Optics and Mechanics

Σχετικές προτάσεις
  • 85000W laser cutting machine emerged and led the world

    Recently, Pentium Laser and Shenzhen Chuangxin Laser launched the world's first 85000W laser cutting machine, once again breaking the record for the highest power in the cutting field.Zhang Qingmao, Director of the Laser Processing Committee of the Chinese Optical Society, Xu Xia, rotating CEO of Pentium Group, Cai Liang, Director of the Final Inspection Department of Pentium Laser Manufactu...

    2023-09-16
    Δείτε τη μετάφραση
  • The influence of laser beam drift on SLM thin-walled TC11 specimens at high scanning speed

    AbstractDue to the width of the laser melt pool and the sintering effect on the surrounding powder, the experimental size of the selective laser melting (SLM) sample will be larger than the design size, which will greatly affect the dimensional accuracy and surface quality of the thin-walled sample. In order to obtain SLM thin-walled TC11 specimens with precise dimensions, an orthogonal experiment...

    02-24
    Δείτε τη μετάφραση
  • Mycronic receives first order after upgrading solid-state lasers

    Recently, Mycronic AB received its first order from SK Electronics in Japan to upgrade the installed display mask writer from a gas laser to a solid-state laser. The upgrade is scheduled to be delivered within the next two years.Image source: MycronicIt is reported that Mycronic's "Pattern Generators" department provides mask writers for display manufacturing and semiconductor production. So far, ...

    2023-10-16
    Δείτε τη μετάφραση
  • Automated methods for background estimation in laser spectroscopy

    A new automated method for spectral background estimation in laser spectroscopy ensures the accuracy of quantitative analysis with minimal human intervention.When using laser-induced breakdown spectroscopy in spectral analysis, scientists may encounter various obstacles. The most common challenge faced by scientists when conducting elemental analysis is to optimize the interaction between the lase...

    2023-11-24
    Δείτε τη μετάφραση
  • The Boston University research team developed a high-throughput single-cell sorting technique based on stimulated Raman spectroscopy

    A Boston University research project has successfully developed an innovative single-cell sorting technique that uses stimulated Raman spectroscopy to replace traditional fluorescent labeling and achieve labeling free and non-destructive single-cell measurements. This technology is expected to have a profound impact in the fields of cytology, microbiology and biomedical research, allowing scienti...

    2023-09-07
    Δείτε τη μετάφραση