As a key component in precision control systems, the performance of servo motor power heads directly affects the efficiency, accuracy, and stability of the equipment. Optimizing the performance of servo motor power heads can not only improve production efficiency, but also extend equipment lifespan and reduce failure rates. Here are several effecti...
03-251700In modern automation control systems, servo cables serve as key components connecting servo drives and servo motors, and their performance stability and reliability are crucial. However, in practical applications, the problem of poor contact of servo cable joints often occurs, which not only affects the normal operation of the equipment, but may al...
03-201911When choosing a linear motor, in order to ensure the selection of the most suitable model for your needs, it is necessary to comprehensively consider the following key parameters:1、 Model and sizeFirstly, the model and size of the motor should be determined based on the limitations of the application space and the requirements of the workload. Di...
02-274100When repairing the grounding fault of the armature winding of a DC motor, we can use various techniques. Firstly, it is necessary to ensure the use of convenient and practical maintenance tools, such as armature maintenance lights. Connect the lamp to the circuit and clarify the fault situation through the operation method. If the light is on after...
02-185800Possible causes of malfunction:Excessive clearance of bearings due to wear and tear;Uneven air gap affects the balance of the motor;Unbalanced rotor leads to vibration;The bending deformation of the shaft affects the operation of the motor;Iron core deformation or looseness, affecting the stability of the motor;The center of the coupling (or pulley...
02-1791001、 Analysis of the causes of oil leakage in the gearbox:Oil leakage is more common in gearboxes, with particularly prominent leakage at the seals of the drive and driven shaft heads, especially at the sealing ring of the drive shaft. In addition, there are three other common oil leakage locations, including oil leakage along the gearbox joint surfa...
02-085801With the development of the industrial industry, brushless DC motors, as a commonly used type of electric motor, have become increasingly widely used due to their high efficiency, high speed, and low noise. At the same time, their equipment maintenance and upkeep are also receiving more attention. So, what are the common faults of brushless DC moto...
01-158400Frequency converters are widely used in modern industry, but sometimes there are occasional trips that cause inconvenience to production. Below, we will analyze the common causes of frequency converter tripping and provide corresponding solutions.Overload causes trippingOverload is one of the common causes of frequency converter tripping. When th...
01-148400We are a professional manufacturer of Precision circular two roll plate rolling machine with over 10 years of industry experience. Today, we would like to introduce to you: The Precision circular two roll plate rolling machine is a device used for shaping metal sheets, mainly achieving bending and forming of the sheet through the interaction of t...
2024-12-2313511We are a professional Stable operation of Stable operation of hydraulic punch press manufacturer with over 10 years of industry experience. Today, we would like to introduce to you:https://www.sdsmachinery.comStable operation of hydraulic punch press is a type of punch press that uses hydraulic cylinders to generate compressive force and belongs ...
2024-12-23132111、 Motor burnt outOne of the common faults of brushless DC motors is motor burnout. Possible reasons include overvoltage, overload, overheating, etc. If the motor is found to be burnt out, it is necessary to replace the motor and check whether the relevant circuits are working properly.2、 Controller malfunctionThe controller is a very important c...
2024-12-079910Reasons for unstable power of synchronous motors1. Poor circuit connection: The circuit connection of synchronous motors, such as poor circuit connection and poor contact of contacts, can lead to unstable motor power.2. Mechanical load changes: The operating environment and load changes of synchronous motors can affect the output power of the moto...
2024-11-2897101. Autotransformer starting method: The starting voltage of the motor is reduced through an autotransformer. During the starting process, the motor is first connected to the lower voltage side of the autotransformer, and then the voltage is gradually increased to gradually accelerate the motor. After the motor reaches its rated speed, connect it to...
2024-11-25102001、 Phase failurePhase failure is one of the common faults in permanent magnet synchronous motors, which may be caused by poor contact of power lines, wiring faults in windings, or burnt windings. If there is a phase failure in the permanent magnet synchronous motor, the first thing to check is the power cord, winding, and other parts. If poor conta...
2024-09-068610Reducer is one of the core components in the industrial field, which can convert the power output of high-speed movement motor deceleration, in order to suit the needs of various equipment in industrial production. There are many classifications of speed reducers, and the four major series of speed reducers are planetary speed reducers, hard-toothe...
2024-08-228601